Engineering: Engineering consists of: * But is not limited to - Preliminary site visits, with the customer, to determine the project needs.
- Equipment, battery and cable sizing calculations, for present site requirements, with growth over-build, per the customers’ needs.
- Drafting a project specific scope of work (SOW) and method of procedure (MOP) for each task to be performed.
- Periodic site visits for quality control and progress reporting.
- Represent the interests of the customer, on-site, during all planning stages of on-going new construction or existing build-out projects.
- Assist the customer in site selection based on location and building accessibility. (Both physically for equipment installation and logistically for connection to existing transmission lines.)
- Engineer the most fail-safe methods for keeping revenue-generating equipment "on-line". (This would apply in the design, installation and connection to, all electrical systems.).
- Design power rooms to serve present load requirements as well as future growth, at a rate of approximately fifteen percent (15%) growth, per year.
- Consult with different equipment manufacturers about their newest equipment designs and select the equipment that will provide : a) Optimum performance, b) Cost effectiveness, c) Expansion capabilities and d) Warranty/Service Agreement
- Insure the most cost effective and timely installations by working directly with the Architectural/Engineering firms, as a customer representative
- Assist in the selection of contractors to perform the electrical installations.
- Support the customers’ implementation team with timely progress reports for each project.
- Oversee the installations with site visits to assure that all time-lines are met.
- Provide an upgraded growth path to newer technology.
|
Remedial Service: Remedial Service consists of: * But is not limited to - Any corrective-action service required for maintaining or repairing existing equipment.
- Remedial service calls have a maximum response interval of 24 hours.
- Constant Current, per availability from the equipment manufacturer will supply any and all parts needed for remedial service.
- (Constant Current will assume no responsibility for any data, revenue, and labor or equipment losses due to the unavailability of parts.)
|
Preventive Maintenance For Batteries, Rectifiers and DC Power Plants: Preventive Maintenance consists of annual, semi-annual or monthly DC plant survey and testing. The breakdown of services provided with each are as follows: BATTERY PLANT MAINTENANCE | BI-MONTHLY | SEMI-ANNUAL | ANNUAL | BY REQUEST | Check general appearance and cleanliness | YES | YES | YES | YES | Check cells for cracks or electrolyte leaks | YES | YES | YES | YES | Check inter-cell busses for corrosion | YES | YES | YES | YES | Check connections and re-torque | BCR | YES | YES | YES | Check electrolyte levels * | YES | YES | YES | YES | Check felt pads * | YES | YES | YES | YES | Check ambient temperature and ventilation | YES | YES | YES | YES | Check integrity of battery racks | YES | YES | YES | YES | Measure electrolyte temperature @ pilot cell * | YES | YES | YES | YES | Measure specific-gravity @ pilot cell * | YES | YES | YES | YES | Measure specific-gravity of all cells * | BCR | YES | YES | YES | Measure cell voltages of all cells | YES | YES | YES | YES | Perform termination resistance check | NO | NO | YES | YES | Battery "Service" dischargetest (w/bldg. load) | BCR | BCR | BCR | YES | Battery "Performance" discharge test (w/ load-bank) | BCR | BCR | BCR | YES | Calculate approximate reserve time | BCR | BCR | YES | YES | (* Wet cell plants only.) BCR-by customer request RECTIFIER PLANT MAINTENANCE | BI-MONTHLY | SEMI-ANNUAL | ANNUAL | BY REQUEST | Check general appearance and cleanliness | YES | YES | YES | YES | Check equipment and cable labeling | YES | YES | YES | YES | Check alarm setup and calibration | YES | YES | YES | YES | Check meter calibration | YES | YES | YES | YES | Check parallel operation (load-sharing) | YES | YES | YES | YES | Check float voltage | YES | YES | YES | YES | Check equalize voltage | YES | YES | YES | YES | Check current-limit threshold | BCR | YES | YES | YES | Check high-voltage-shutdown threshold | BCR | YES | YES | YES | Check capacitor integrity | BCR | BCR | YES | YES | Check operation of all breakers | BCR | BCR | YES | YES | Perform infra-red heat scan | BCR | BCR | BCR | YES | BCR-by customer request POWERBOARD MAINTENANCE | BI-MONTHLY | SEMI-ANNUAL | ANNUAL | BY REQUEST | Check general appearance and cleanliness | YES | YES | YES | YES | Check equipment and cable labeling | BCR | YES | YES | YES | Check alarm setup and calibration | YES | YES | YES | YES | Check meter calibration | YES | YES | YES | YES | Check cable voltage drop to loads | BCR | BCR | YES | YES | Check existing load vs. capacity of MDB | YES | YES | YES | YES | Check Low-Voltage-Disconnect setting | BCR | BCR | YES | YES | Perform infra-red heat scan | BCR | BCR | BCR | YES | BCR-by customer request
|
|
|
|
|